<LOGO>
FM Transmitter Measurement Report
Created: 2023-04-20 15-43-50
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
100.20 MHz 5/5, 40 dBuV INTER
Pilot RDS Phase Difference
7.3 kHz 2.6 kHz 53 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
11 kHz 74 kHz 5537 1,2100
Modulation Power
Limit Measuring Tolerance
9,0 dBr 0,0 dBr
MIN AVE MAX % above 9,0 dBr
1,6 dBr 3,22 dBr 5,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" INTER " F201 0 (No PTY) 1 0 1 1 15:43, 20.04.2023
RT
"AFFAIRES SENSIBLES - FRANCE INTER 1ERE RADIO DE FRANCE "
AF EON
87.8, 88.1, 92.6, 93.0, 93.2, 93.8, 94.6, 94.9, 95.0, 95.1, 96.3, 96.5, 96.8, 99.2, 99.4, 99.5, 99.6, 99.9, 100.2, 100.7, 101.9 MHz F209, F202, F206, F203
FM Scope Station: 100.20 MHz, signal: 5/5 (40 dBuV) Max at: 74 kHz MIN: 11 kHz % above 75 kHz: 1,2100 Acquired: 2023/04/20 15:42:46 Total samples: 5537 Equivalent time: 0:04:36 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150
FM Scope MAX: 5,3 dBr MIN: 1,6 dBr AVE: 3,22 dBr % above 9,0 dBr: 0,0 Last value: 1,6 dBr (2023/04/20 15:42:45) Station: 100.20 MHz, signal: 5/5 (40 dBuV) 15:30 15:32 15:34 15:36 15:38 15:40 15:42 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality